佳能6075出現(xiàn)E000066-0002故障代碼是怎么問題
Description:
Pre-transfer Charging Shutter HP close error.
The Pre-transfer Charging Shutter Sensor (PS95) detects that the shutter is closed although it is moved to the open position.
佳能6055機(jī)器報(bào)e000066-0002
Description:
Pre-transfer Charging Shutter HP close error.
The Pre-transfer Charging Shutter Sensor (PS95) detects that the shutter is closed although it is moved to the open position.
佳能6075報(bào)錯E000066-0002是什么原因
佳能6075錯誤提示手機(jī)用戶180.12.*.*2020-3-9 8004
佳能6075跳代碼手機(jī)用戶180.12.*.*2020-3-9 8004
佳能6075打印臟衛(wèi)虐辨2020-3-9 有完整代碼嗎,這個代碼查不到
佳能6075相城區(qū)維修點(diǎn)HH3262202021/11/19 蘇州佳能6075批發(fā)Code: E066-0002
Description:
Pre-transfer Charging Shutter hp close error.
The Pre-transfer Charging Shutter Sensor (PS95) detects that the shutter is closed although it is moved to the open position.
Remedy:
1. Check the position of the Pre-transfer Charging Shutter. 1-A. In the case that the Pre-transfer Charging Shutter fails to operate (stopped at hp at front side) Check the connection of the Pre-transfer Charging Wire Cleaning Motor (M7). Sensor side: J3108, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2)) 1-B. In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position) 1-B-1. Check that the Primary Fan Duct is closed. Close the Primary Fan Duct. 1-B-2. Check movement of the pin to push the Pre-transfer Charging Shutter Sensor (PS95). Replace the Pin. 1-B-3. Check movement of the flag on the Pre-transfer Charging Shutter Sensor (PS95). Replace the flag/ spring. 1-B-4. Check the connection of the Pre-transfer Charging Shutter Sensor (PS95). Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2)) 1-C. In the case that the Pre-transfer Charging Shutter is stopped along the way 1-C-1. Check abrasion of the Slider Pin. Replace the Slider Pin. 1-C-2. Replace the Pre-transfer Charging Assembly. 2. Replace the DC Controller PCB (PCB1).
佳能8105E000066-0002是怎么了
佳能8105小六2018/5/6 15:08:32E000066-0001可能是廢墨粉滿檢測傳感器故障--主電機(jī)在旋轉(zhuǎn)的時(shí)候連續(xù)五秒以上檢測到廢墨粉滿狀態(tài)。
對 策: 檢查廢墨粉滿傳感器插頭。更換廢墨粉滿傳感器。更換DC 控制電路板;蛘呦到y(tǒng)斷電5-10分鐘后重啟,如果仍然有此提示,這個故障是您自己不能排除的故障。具體故障需要聯(lián)系佳能維修站檢測。蘇州用戶聯(lián)系我們處理.