美能達5501/6501報錯代碼C-4520,C4520解決方法
更新時間:2025/2/9 4:07:29,view:206美能達打印機蘇州美能達打印機售后服務(wù)中心客服熱線69616769,蘇州美能達售后電話,美能達售后網(wǎng)點, 美能達bizhub7718打印機維修召喚m2, 美能達c210復(fù)印機成像單元, 美能達1700打印機出現(xiàn)錯誤, 美能達195出現(xiàn)0211,維修視頻
美能達5501/6501報錯代碼C-4520,C4520解決方法
Cause
Colour registration adjustment failure
Resolution
Step 1.
C-4520
Step 2.
Toner Density Revert
1. Power the machine OFF from the main switch leaving the sub switch ON.
2. Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
3. -02 Select process adj
4. -02 Select drum peculiarity
5. -06 Select toner density revert - run that routine. All values need to be circa 1.26
for 5500/6500 - should be under sensor output check - density return mode
max density sensor
6. Press the [Return] key, which is displayed on the touchscreen.
7. Exit Service mode to return to normal operation
Gamma Automatic Adjustment
1. Power the machine OFF from the main switch leaving the sub switch ON.
2. Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
3. -02 process adjustment
4. -06 recall standard data
5. -02 drum peculiarity
6. -06 toner revert all on
7. -02 gamma automatic adjust (wait for procedure to complete)
Colour Registration Adjustment
1. -01 Machine Adjustment
2. -01 Printer Adjustment
3. -10 Colour Registration Adjustment (wait for operation to complete)
4. - When completed exit out of service mode.
Exit out of service mode and go into adjustment at the bottom of the screen.
1. -03 execute adjust operation
2. Select toner refresh mode press ok. 蘇州美能達打印機維修站電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送
Cause
Colour registration adjustment failure
Resolution
Step 1.
C-4520
Step 2.
Toner Density Revert
1. Power the machine OFF from the main switch leaving the sub switch ON.
2. Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
3. -02 Select process adj
4. -02 Select drum peculiarity
5. -06 Select toner density revert - run that routine. All values need to be circa 1.26
for 5500/6500 - should be under sensor output check - density return mode
max density sensor
6. Press the [Return] key, which is displayed on the touchscreen.
7. Exit Service mode to return to normal operation
Gamma Automatic Adjustment
1. Power the machine OFF from the main switch leaving the sub switch ON.
2. Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
3. -02 process adjustment
4. -06 recall standard data
5. -02 drum peculiarity
6. -06 toner revert all on
7. -02 gamma automatic adjust (wait for procedure to complete)
Colour Registration Adjustment
1. -01 Machine Adjustment
2. -01 Printer Adjustment
3. -10 Colour Registration Adjustment (wait for operation to complete)
4. - When completed exit out of service mode.
Exit out of service mode and go into adjustment at the bottom of the screen.
1. -03 execute adjust operation
2. Select toner refresh mode press ok. 蘇州美能達打印機維修站電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送