Code: U6-83
Description:
Room temperature thermistor breakdown (1 series)
Causes:
Room temperature thermistor harness connection trouble Room temperature thermistor trouble A3 2-stage LCT control PWB trouble
Remedy:
Check connection of the harness and the connector of the room temperature thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Code: U6-84
Description:
Room humidity thermistor breakdown (1 series)
Causes:
Humidity thermistor harness connection trouble Humidity thermistor trouble A3 2-stage LCT control PWB trouble
Remedy:
Check connection of the harness and the connector of the humidity thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Code: U6-85
Description:
Transport motor 1 trouble (2 series)
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the transport motor. Replace the motor. Replace the A3 2-stage LCT control PWB.
Code: U6-86
Description:
24V power trouble (2 series)
Causes:
Connection trouble or disconnection of the connector and the harness. A3 2-stage LCT control PWB trouble Power unit trouble
Remedy:
Check the connector and the harness of the power line. Check the 24V voltage with the power unit and the A3 2-stage LCT control PWB.
Code: U6-87
Description:
Power unit cooling fan motor trouble (2 series)
Causes:
Motor lock, motor harness short/open, A3 2-stage LCT control PWB trouble, harness and connector connection trouble
Remedy:
Check connection from the A3 2-stage LCT control PWB to the motor. Replace the A3 2-stage LCT control PWB. Replace the motor.

Code: U6-88
Description:
EEPROM trouble (2 series)
Causes:
A3 2-stage LCT control PWB trouble Malfunction caused by noises
Remedy:
Replace the A3 2-stage LCT control PWB.
Code: U6-89
Description:
Room temperature thermistor breakdown (2 series)
Causes:
Room temperature thermistor harness connection trouble Room temperature thermistor trouble A3 2-stage LCT control PWB trouble
Remedy:
Check connection of the harness and the connector of the room temperature thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Code: U6-90
Description:
Room humidity thermistor breakdown (2 series)
Causes:
Humidity thermistor harness connection trouble Humidity thermistor trouble A3 2-stage LCT control PWB trouble
Remedy:
Check connection of the harness and the connector of the humidity thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Code: U7-50
Description:
MFPC PWB - Vendor machine communication error
Causes:
Improper setting of the vendor machine specifications (SIM26-3). Vendor machine trouble. MFPC PWB trouble. Connector, harness connection trouble. Strong external noises.
Remedy:
Cancel the error by turning OFF/ON the power. Check the connector and the harness in the communication line. Change the specifications of the vendor machine (SIM26-3). Replace the MFPC PWB.
Code: U7-51
Description:
Vendor machine error
Causes:
Serial vendor machine trouble. Connector, harness connection trouble
Remedy:
Err.XX is displayed on the operation panel of the vendor. (XX is the detail code.) Repair the vendor machine referring to the detail code. Check the connector and the harness in the communication line.
Code: U9-01
Description:
Touch panel trouble
Causes:
SUC PWB trouble
Remedy:
Check connection signal between the SCU CPU and the touch panel controller.
Code: UC-02
Description:
IPD/DOCC-ASIC (CPT function) trouble
Causes:
SCU PWB trouble. (IPD/DOCC-ASIC trouble.)
Remedy:
Replace the SCU PWB
Code: UC-12
Description:
IPD/DOCC-ASIC (CPT function) trouble [DSPF detection]
Causes:
DSPF PWB trouble (IPD/DOCC-ASIC trouble).
Remedy:
Replace the DSPF PWB.
Code: UC-20
Description:
IPD/DOCC-ASIC (DOCC function) trouble
Causes:
SCU PWB trouble. (IPD/DOCC-ASIC trouble.)
Remedy:
Replace the SCU PWB.
Code: UC-30
Description:
IPD/DOCC-ASIC (DOCC function) trouble [DSPF detection]
Causes:
DSPF PWB trouble (IPD/DOCC-ASIC trouble).
Remedy:
Replace the DSPF PWB.
Code: UE-10
Description:
LCT1 suction fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SCheck the harness and the connector from the warm air heater (thermistor) to the A3 2-stage LCT control PWB.IM04-03 to check the operation of the suction fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT control PWB.
Code: UE-11
Description:
LCT1 exhaust fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the exhaust fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT control PWB.
Code: UE-12
Description:
LCT1 warm air heater thermistor open
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble
Remedy:
Check the harness and the connector from the warm air heater (thermistor) to the A3 2-stage LCT control PWB.
Code: UE-13
Description:
LCT1 warm air heater thermistor low temperature trouble
Causes:
Warm air heater (thermistor) trouble Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-14
Description:
LCT1 warm air heater thermistor high temperature trouble
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-15
Description:
LCT1 warm air outlet port thermistor open
Causes:
Thermistor trouble. A3 2-stage LCT control PWB trouble Connector connection trouble
Remedy:
Check connection of the harness and the connector from the thermistor to the A3 2-stage LCT control PWB.

Code: UE-16
Description:
LCT1 warm air outlet port thermistor low temperature
Causes:
Thermistor trouble. Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-17
Description:
LCT1 warm air outlet port thermistor high temperature
Causes:
Thermistor trouble. Warm air heater harness and connector connection trouble Heater relay PWB trouble A3 2-stage LCT control PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-20
Description:
LCT2 suction fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the suction fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT controller PWB.
Code: UE-21
Description:
LCT2 exhaust fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the exhaust fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT control PWB.
Code: UE-22
Description:
LCT2 warm air heater thermistor open
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble
Remedy:
Check the harness and the connector from the warm air heater (thermistor) to the A3 2-stage LCT control PWB.
Code: UE-23
Description:
LCT2 warm air heater thermistor low temperature trouble
Causes:
Warm air heater (thermistor) trouble Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-24
Description:
LCT2 warm air heater thermistor high temperature trouble
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-25
Description:
LCT2 warm air outlet port thermistor open
Causes:
Thermistor trouble. A3 2-stage LCT control PWB trouble Connector connection trouble
Remedy:
Check connection of the harness and the connector from the thermistor to the A3 2-stage LCT control PWB.

Code: UE-26
Description:
LCT2 warm air outlet port thermistor low temperature
Causes:
Thermistor trouble. Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-27
Description:
LCT2 warm air outlet port thermistor high temperature
Causes:
Thermistor trouble. Warm air heater harness and connector connection trouble Heater relay PWB trouble A3 2-stage LCT control PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-30
Description:
LCT3 suction fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the suction fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT control PWB.
Code: UE-31
Description:
LCT3 exhaust fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the exhaust fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT control PWB.
Code: UE-32
Description:
LCT3 warm air heater thermistor open
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble
Remedy:
Check the harness and the connector from the warm air heater (thermistor) to the A3 2-stage LCT control PWB.
Code: UE-33
Description:
LCT3 warm air heater thermistor low temperature trouble
Causes:
Warm air heater (thermistor) trouble Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-34
Description:
LCT3 warm air heater thermistor high temperature trouble
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-35
Description:
LCT3 warm air outlet port thermistor open
Causes:
Thermistor trouble. A3 2-stage LCT control PWB trouble Connector connection trouble
Remedy:
Check connection of the harness and the connector from the thermistor to the A3 2-stage LCT control PWB.

Code: UE-36
Description:
LCT3 warm air outlet port thermistor low temperature
Causes:
Thermistor trouble. Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-37
Description:
LCT3 warm air outlet port thermistor high temperature
Causes:
Thermistor trouble. Warm air heater harness and connector connection trouble Heater relay PWB trouble A3 2-stage LCT control PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-40
Description:
LCT4 suction fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the suction fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT controller PWB.
Code: UE-41
Description:
LCT4 exhaust fan motor trouble
Causes:
Motor lock Motor RPM abnormality Overcurrent to the motor Harness and connector connection trouble A3 2-stage LCT control PWB trouble
Remedy:
Use SIM04-03 to check the operation of the exhaust fan motor. Check connection of the harness and the connector. Replace the A3 2-stage LCT controller PWB.
Code: UE-42
Description:
LCT4 warm air heater thermistor open
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble
Remedy:
Check the harness and the connector from the warm air heater (thermistor) to the A3 2-stage LCT control PWB.
Code: UE-43
Description:
LCT4 warm air heater thermistor low temperature trouble
Causes:
Warm air heater (thermistor) trouble Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-44
Description:
LCT4 warm air heater thermistor high temperature trouble
Causes:
Warm air heater (thermistor) trouble A3 2-stage LCT control PWB trouble Warm air heater harness and connector connection trouble Heater relay PWB trouble
Remedy:
Check the warm air heater (thermistor) and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.
Code: UE-45
Description:
LCT4 warm air outlet port thermistor open
Causes:
Thermistor trouble. A3 2-stage LCT control PWB trouble Connector connection trouble
Remedy:
Check connection of the harness and the connector from the thermistor to the A3 2-stage LCT control PWB.

Code: UE-46
Description:
LCT4 warm air outlet port thermistor low temperature
Causes:
Thermistor trouble. Warm air heater trouble Warm air heater harness and connector connection trouble A3 2-stage LCT control PWB trouble Thermostat trouble. AC power trouble Insertion detection switch 2 trouble Heater relay PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check for disconnection of the warm air heater and the thermostat. Check the insertion detection switch 2. Check the heater relay PWB. Check the heater control circuit of the AC PWB and that of the A3 2-stage LCT control PWB.
Code: UE-47
Description:
LCT4 warm air outlet port thermistor high temperature
Causes:
Thermistor trouble. Warm air heater harness and connector connection trouble Heater relay PWB trouble A3 2-stage LCT control PWB trouble
Remedy:
Check the thermistor and its harness. Check the thermistor input circuit section of the A3 2- stage LCT control PWB. Check the heater relay PWB. Check the heater control circuit of the A3 2-stage LCT control PWB.

熱門圖文

相關(guān)資料補充_蘇州sharp維修點售后電話_5維修手冊_錯誤代碼0512-69616769 更新日期2025/1/12 16:54:20

»SHARPAR-2008D中有個像小人的圖片亮紅燈是什么意思 101

»SHARP打印機紙盒架發(fā)生錯誤F3-12 201

»sharpAR-4821D打印機出現(xiàn)了那個三角的紅色一直亮著怎么回事 1203

»SHARPAR4021打印機小人和太陽亮紅燈是什么情況 1055

»sharpar2008d打印機卡紙怎么辦 60

»sharp2658N打印機發(fā)生錯誤H5-01 65

»施樂掃描錯誤異常結(jié)束(018-543)sharednameerrorinserver 718

»sharp打印機顯示九個圓點組成的三角形是 476

»sharpar2008d開機三角形的六個點在閃爍 83

»SHARP復印機錯誤碼L4-03 70

»sharp4818打印機出現(xiàn)錯誤代碼L4-03是什么問題? 1389

»sharp1808S掃描儀顯示U-2 135

»SHARPAR-1808S打印機重置怎重置?? 864

»SHARPMX-M2608NPCL6錯誤代碼F2-64 77

»Sharp MXM550U常見故障代碼描述,英文手冊02 93


sharp打印機SharpMXM1055蘇州黃埭sharp售后服務(wù)電話0512-696l6769,蘇州sharpSharpMXM1055售后電話,sharpSharpMXM1055黃埭售后網(wǎng)點,sharpSharpMXM1055維修手冊,sharpSharpMXM1055驅(qū)動程序下載,sharpSharpMXM1055打印機售后維修點,sharpSharpMXM1055廠家電話,故障代碼在線技術(shù)交流,有問必答,sharpSharpMXM1055卡紙,打印淺,亮紅燈,不通電,無法使用等故障自己查詢維修資料即可解決問題