Code: C2 10
Description:
Image density sensor error/ Transfer charger error (Black)
Causes:
Black image density sensor trouble /Transfer trouble (Black) /The deference between the transfer belt surface detection level and the black toner patch density detection level is normal. (Judged in black image density sensor calibration)
Remedy:
Case 1 Cause Black image density sensor trouble Check & Remedy Black density image sensor cleaning, replacement Case 2 Cause Transfer voltage trouble Check & Remedy Check and adjust the transfer voltage. Case 3 Cause High voltage PWB trouble Check & Remedy Replace the high voltage PWB. Case 4 Cause Transfer unit trouble Check & Remedy Check the transfer belt surface for dirt and scratches. Replace the transfer belt, replace the cleaning blade, replace the transfer unit. Case 5 Cause PCU PWB trouble Check & Remedy PCU PWB replacement Case 6 Cause Photoconductor unit trouble Check & Remedy Replace the photoconductor unit. Case 7 Cause Developing unit trouble Check & Remedy Replace the developing unit Case 8 Cause Connector, harness trouble (PCU PWB, high voltage PWB, image density sensor, photoconductor unit, transfer unit, developing unit) Check & Remedy Check contact. Replace the harness. Replace the PWB.
Code: E7 01
Description:
Image data memory trouble
Causes:
The ICU image data memory (SDRAM) cannot be detected as 256MB or more. The required SDRAM capacity for the model is not provided.
Remedy:
Case 1 Cause The SDRAM of ICU PWB is not installed. The SDRAM of ICU PWB is improperly installed. Check & Remedy Check installation of the SDRAM of ICU ASIC PWB. Case 2 Cause The SDRAM of ICU PWB does not operate properly. Check & Remedy Use SIM 60-01 to check the capacity of the SDRAM. Replace the SDRAM of ICU PWB. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 07
Description:
ICU gate array trouble
Causes:
An abnormality occurs in the ICU gate array.
Remedy:
Case 1 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB. Case 2 Cause Gate array (ASIC, FPGA) abnormality on the ICU PWB Check & Remedy Replace the gate array on the ICU PWB.
Code: E7 10
Description:
Shading trouble (Black correction)
Causes:
CCD black reading level abnormality when the copy lamp is off.
Remedy:
Case 1 Cause Improper installation of the flat cable to the CCD unit. Check & Remedy Check installation of the flat cable to the CCD unit. Case 2 Cause CCD unit abnormality Check & Remedy Check the CCD unit. Case 3 Cause MFP PWB abnormality Check & Remedy Check the MFP PWB.
Code: E7 11
Description:
Shading trouble (White correction)
Causes:
CCD white reading level abnormality when the copy lamp is off.
Remedy:
Case 1 Cause Improper installation of the flat cable to the CCD unit. Check & Remedy Check installation of the flat cable to the CCD unit. Case 2 Cause Dirt on the mirror, the lens, or the reference white plate. Check & Remedy Clean the mirror, the lens, or the reference white plate. Case 3 Cause CCD unit abnormality Check & Remedy Check the CCD unit. Case 4 Cause MFP PWB abnormality Check & Remedy Check the MFP PWB.
Code: E7 20
Description:
LED controller initial trouble (Black)
Causes:
The initial process of the LED controller cannot be completed properly.
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 21
Description:
LED controller initial trouble (Cyan)
Causes:
The initial process of the LED controller cannot be completed properly.
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 22
Description:
LED controller initial trouble (Magenta)
Causes:
The initial process of the LED controller cannot be completed properly.
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 23
Description:
LED controller initial trouble (Yellow)
Causes:
The initial process of the LED controller cannot be completed properly.
Remedy:
Case 1 Cause Disconnection of the LED head connector Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 24
Description:
LED controller output trouble (Black)
Causes:
When printing, the print end signal for each page is not properly provided
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 25
Description:
LED controller output trouble (Cyan)
Causes:
When printing, the print end signal for each page is not properly provided.
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 26
Description:
LED controller output trouble (Magenta)
Causes:
When printing, the print end signal for each page is not properly provided.
Remedy:
Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 27
Description:
LED controller output trouble (Yellow)
Causes:
When printing, the print end signal for each page is not properly provided.
Remedy:
Case 1 Cause Disconnection of the LED head connector Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
Code: E7 28
Description:
LED control ASIC connection abnormality
Causes:
Access error between the PCU PWB CPU and the LED control ASIC
Remedy:
Case 1 Cause Disconnection of the ICU/ PCU PWB communication connector Check & Remedy Check connection of the ICU/PCU PWB communication connector Case 2 Cause ICU/PCU PWB communication harness trouble. Check & Remedy Check the ICU/PCU PWB communication harness. Case 3 Cause ICU PWB/PCU PWB trouble Check & Remedy Check grounding of the machine. Replace the IC
Code: E7 40
Description:
Color correction data write error
Causes:
Data write error to the Nand-Flash for holding color correction data
Remedy:
Case 1 Cause Color correction data rewrite error Check & Remedy Perform rewriting of color correction data again. Case 2 Cause MFP PWB trouble Check & Remedy Replace the MFP PWB.
Code: E7 41
Description:
Color correction data transfer abnormality
Causes:
Data transfer error from the Nand-Flash for holding color correction data to the FC-RAM for holding color correction image process
Remedy:
Replace the MFP PWB.
Code: E7 80
Description:
ICU-SCN communication trouble (ICU detection)
Causes:
Communication establishment error, framing, parity, protocol error
Remedy:
Case 1 Cause Disconnection of the ICU/ MFP PWB scanner communication connector. Defective harness of the ICU PWB and the MFP PWB. Check & Remedy Check connection of the ICU PWB and the MFP PWB. Check the harness. Case 2 Cause ICU/MFP PWB trouble Check & Remedy Check grounding of the machine. Replace the ICU PWB or the MFP PWB.
Code: E7 90
Description:
ICU-PCU communication trouble (ICU detection)
Causes:
Communication establishment error, framing, parity, protocol error
Remedy:
Case 1 Cause Disconnection of the ICU/ PCU PWB scanner communication connector. Defective harness of the ICU PWB and the PCU PWB. Check & Remedy Check connection of the ICU PWB and the PCU PWB. Check the harness. Case 2 Cause ICU/PCU PWB trouble Check & Remedy Check grounding of the machine. Replace the ICU PWB or the PCU PWB.
Code: F1 00
Description:
Finisher communication trouble (Machine detection)
Causes:
Communication line test error when turning on the power or after canceling the exclusive simulation. Communication error with the finisher.
Remedy:
Case 1 Cause Disconnection of the PCUfinisher connector, defective contact or disconnection of the harness. Check & Remedy Check the connector and the harness of the communication line. Case 2 Cause Finisher control PWB trouble Check & Remedy Replace the finisher control PWB. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB. Case 4 Cause Malfunctions by noises Check & Remedy — Common Cancel method Can be canceled by turning OFF/ON the power.
Code: F1 02
Description:
Finisher transport motor trouble (Finisher detection)
Causes:
Transport motor drive trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the transport motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 03
Description:
Finisher paddle motor trouble
Causes:
Paddle motor operation trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 06
Description:
Finisher slide motor trouble
Causes:
Slide motor operation trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 10
Description:
Finisher staple motor trouble (Finisher detection)
Causes:
Stapling operation trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 11
Description:
Finisher bundle process motor trouble (Finisher detection)
Causes:
Bundle process motor trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.

Code: F1 15
Description:
Finisher tray lift motor trouble (Finisher detection)
Causes:
Lift motor trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 19
Description:
Finisher front alignment motor trouble (Finisher detection)
Causes:
Front alignment motor trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 20
Description:
Finisher rear alignment motor trouble (Finisher detection)
Causes:
Rear alignment motor trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 31
Description:
Finisher fold sensor trouble
Causes:
Sensor input value abnormality
Remedy:
Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 32
Description:
Finisher punch unit communication trouble
Causes:
Communication error between the console finisher and the punch unit
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness of the console finisher and the punch unit. Check & Remedy Check the connector and the harness of the communication line. Case 2 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB. Case 3 Cause Console finisher control PWB trouble Check & Remedy Replace the console finisher control PWB. Case 4 Cause Malfunction by noises Check & Remedy Common Cancel method Can be canceled by turning OFF/ON the power.
Code: F1 33
Description:
Finisher punch side registration motor trouble
Causes:
Punch side registration motor operation trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 34
Description:
Finisher punch motor trouble
Causes:
Punch motor operation trouble
Remedy:
Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 35
Description:
Finisher punch side registration sensor trouble
Causes:
Sensor input value abnormality
Remedy:
Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.

Code: F1 36
Description:
Finisher punch registration sensor trouble
Causes:
Sensor input value abnormality
Remedy:
Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 37
Description:
Finisher/sorter backup RAM trouble
Causes:
Writing to the backup RAM is started but not completed in 250msec. When writing to the backup RAM, if the write data do not coincide with the read data, writing is performed again. However, the write data still do not coincide with the read data.
Remedy:
Case 1 Cause Console finisher control PWB, backup RAM trouble Check & Remedy Replace the console finisher control PWB. Case 2 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1. Case 3 Cause Sorter control PWB, backup RAM trouble Check & Remedy Replace the sorter control PWB, and perform the bin paper sensor sensitivity adjustment and the guide bar motor oscillation range adjustment. Case 4 Cause Sorter control PWB trouble Check & Remedy Same as Case 3. Case 5 Cause Malfunction caused by noises Check & Remedy Turn off the machine power, and turn it on again.
Code: F1 38
Description:
Finisher punch backup RAM trouble
Causes:
Abnormal transformation of punch unit backup RAM contents
Remedy:
Case 1 Cause Punch control PWB trouble Check & Remedy Replace the punch control PWB. Case 2 Cause Malfunction caused by noises
Code: F1 39
Description:
Finisher punch dust sensor trouble
Causes:
Punch dust sensor detection trouble
Remedy:
Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as Case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 40
Description:
Finisher punch power disconnection trouble
Causes:
The power disconnection of the punch unit is detected.
Remedy:
Case 1 Cause Harness disconnection Check & Remedy Use SIM 3-3 to check the punching operation. Case 2 Cause Punch control PWB trouble Check & Remedy Same as Case 1.
Code: F1 83
Description:
Guide bar oscillation motor (M3) lock
Causes:
Returning to the home position is not completed in 2sec. When moving from the home position, the home position sensor does not turn off after outputting 20 pulses of the motor drive signal.
Remedy:
Common Check Execute SIM 3-2 and 3-3 to check the guide bar drive motor operations and the sensor operations. Case 1 Cause Guide bar home position sensor trouble Check & Remedy Replace the guide bar home position sensor. Case 2 Cause Cable trouble between the guide bar oscillation motor and the sorter controller PWB. Check & Remedy Check and connect the cable properly between the guide bar oscillation motor and the sorter controller PWB. Case 3 Cause The circuit breaker (CB1) is operating. Check & Remedy Remove the cause for operation of the circuit breaker, and reset the circuit breaker. Case 4 Cause There is a mechanical bur in the guide bar shifting path. Check & Remedy Repair the mechanism to remove the bur. Case 5 Cause Guide bar oscillating motor (M3) trouble Check & Remedy Replace the sorter controller PWB, and perform the bin paper sensor sensitivity adjustment and the guide bar motor oscillating range adjustment. Case 6 Cause Sorter controller PWB trouble Check & Remedy Same as Case 5
Code: F1 89
Description:
Bin shift motor (M1) lock
Causes:
The bin shift motor operation is not completed in 4 times greater than the specified time. When driving the bin shift motor, the signal from the shift motor clock sensor is not detected in 250msec. Shifting to the home position is not completed in 30sec.
Remedy:
Common Check Execute SIM 3-2 and 3-3 to check the guide bar drive motor operations and the sensor operations. (Case 1, 2) Check the voltage (about 24V) between J8-1 and J8-2 on the bin shift motor driver PWB at the timing of the bin shift motor. (Case 3 to 5) Case 1 Cause Cable trouble between the bin shift motor and the sorter controller PWB. Check & Remedy Check and connect the cable properly between the bin shift motor and the sorter controller PWB. Case 2 Cause The circuit breaker (CB1) is operating. Check & Remedy Remove the cause for operation of the circuit breaker, and reset the circuit breaker. Case 3 Cause Wiring trouble of the bin shift motor (M1). Check & Remedy Correct wiring of the bin shift motor. Case 4 Cause Bin shift motor trouble Check & Remedy Replace the bin shift motor. Case 5 Cause Sorter controller PWB trouble Check & Remedy Replace the sorter controller PWB, and perform the bin paper sensor sensitivity adjustment and the guide bar motor oscillating range adjustment. Case 6 Cause Bin shift mechanism trouble Check & Remedy Repair the mechanism.
Code: F1 91
Description:
Bin paper sensor automatic adjustment trouble
Causes:
Sensor output abnormality when adjusting the sensor detection level.
Remedy:
Common Check Execute SIM 3-2 to check the sensor output. Case 1 Cause Cable trouble between the sorter controller PWB and the bin unit. Check & Remedy Check and connect the cable properly between the sorter controller PWB and the bin unit. Case 2 Cause Cable trouble on the light emitting side (S1) and the light receiving side (S2) of the bin paper sensor. Check & Remedy Check and connect the cable properly on the light emitting side (S1) and the light receiving side (S2) of the bin paper sensor. Case 3 Cause Improper installation on the light emitting side (S1) and the light receiving side (S2) of the bin paper sensor. Check & Remedy Install the light emitting side (S1) and the light receiving side (S2) of the bin paper sensor of the bin paper sensor, and perform the bin paper sensor sensitivity adjustment. Case 4 Cause Bin paper sensor light emitting side (S1) and light receiving side (S2) trouble Check & Remedy Replace the bin paper sensor light emitting side (S1) and light receiving side (S2), and perform the bin paper sensor sensitivity adjustment.

Code: F2 15
Description:
Drum cartridge initial detection trouble (Black)
Causes:
Drum cartridge initial detection trouble
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the drum cartridge initial sensor. Connect it properly. 2. Check connection of the connector harness and the PCU PWB. Connect it properly. 3. Check for disconnection of the harness. Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 16
Description:
Drum cartridge initial detection trouble (Cyan)
Causes:
Drum cartridge initial detection trouble
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the drum cartridge initial sensor. Connect it properly. 2. Check connection of the connector harness and the PCU PWB. Connect it properly. 3. Check for disconnection of the harness. Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 17
Description:
Drum cartridge initial detection trouble (Magenta)
Causes:
Drum cartridge initial detection trouble
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the drum cartridge initial sensor. Connect it properly. 2. Check connection of the connector harness and the PCU PWB. Connect it properly. 3. Check for disconnection of the harness.Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 18
Description:
Drum cartridge initial detection trouble (Yellow)
Causes:
Drum cartridge initial detection trouble
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the drum cartridge initial sensor. Connect it properly. 2. Check connection of the connector harness and the PCU PWB. Connect it properly. 3. Check for disconnection of the harness. Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 19
Description:
Transfer unit initial detection trouble
Causes:
Transfer unit initial detection trouble
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy Check connection of the transfer unit initial sensor. Check connection of the connector and the harness of the PCU PWB. Check for disconnection of the harness. Case 2 Cause Unit trouble Check & Remedy Replace the unit.
Code: F2 39
Description:
Process thermistor breakdown
Causes:
Process thermistor open
Remedy:
Case 1 Cause Process thermistor trouble Check & Remedy Replace the process thermistor. Case 2 Cause Disconnection of the process thermistor harness. Check & Remedy Check connection of the connector and the harness of the process thermistor. Case 3 Cause PCU PWB trouble Check & Remedy Replace the PCU PWB.
Code: F2 40
Description:
Toner empty sensor abnormality (Black)
Causes:
Toner empty sensor output abnormality
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the toner empty sensor. - Connect it properly. 2. Check connection of the connector harness to the PCU PWB. - Connect it properly. 3. Check connection of the cartridge. - Connect it properly. 4. Check for disconnection of the harness. - Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 41
Description:
Toner empty sensor abnormality (Cyan)
Causes:
Toner empty sensor output abnormality
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the toner empty sensor. - Connect it properly. 2. Check connection of the connector harness to the PCU PWB. - Connect it properly. 3. Check connection of the cartridge. - Connect it properly. 4. Check for disconnection of the harness. - Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.

Code: F2 42
Description:
Toner empty sensor abnormality (Magenta)
Causes:
Toner empty sensor output abnormality
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the toner empty sensor. - Connect it properly. 2. Check connection of the connector harness to the PCU PWB. - Connect it properly. 3. Check connection of the cartridge. - Connect it properly. 4. Check for disconnection of the harness. - Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge.
Code: F2 43
Description:
Toner empty sensor abnormality (Yellow)
Causes:
Toner empty sensor output abnormality
Remedy:
Case 1 Cause Connector harness trouble, connector disconnection Check & Remedy 1. Check connection of the toner empty sensor. - Connect it properly. 2. Check connection of the connector harness to the PCU PWB. - Connect it properly. 3. Check connection of the cartridge. - Connect it properly. 4. Check for disconnection of the harness. - Replace the harness. Case 2 Cause Cartridge trouble Check & Remedy Replace the cartridge..
Code: F2 44
Description:
Black image density sensor trouble (Transfer belt surface reflection ratio abnormality)
Causes:
Before starting process control, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the output is not within the specified range.
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in SIM 44-2: 1. Dirt/defect of the image density sensor 2. Disconnection of the harness between the PCU PWB and the image density sensor 3. Calibration plate solenoid operation trouble Check & Remedy 1. Clean/replace the image density sensor. 2. Connect/replace the harness between the PCU PWB and the image density sensor. 3. Replace the calibration plate solenoid. Case 2 Cause When SIM 44-2 is completed: 1. Insufficient cleaning of the transfer belt. Check & Remedy 1. Check the transfer belt surface.
Code: F2 45
Description:
Color image density sensor trouble (Calibration plate surface reflection ratio abnormality)
Causes:
Before starting process control, the calibration plate surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the output is not within the specified range.
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in SIM 44-2: 1. Dirt/defect of the image density sensor 2. Disconnection of the harness between the PCU PWB and the image density sensor Check & Remedy 1. Clean/replace the image density sensor. 2. Connect/replace the harness between the PCU PWB and the image density sensor. Case 2 Cause When SIM 44-2 is completed: 1. Dirt on the calibration plate, calibration plate solenoid operation trouble Check & Remedy 1. Clean the calibration plate. Replace the calibration plate solenoid.
Code: F2 58
Description:
Process humidity sensor breakdown
Causes:
Process humidity sensor open
Remedy:
Case 1 Cause Process humidity sensor harness disconnection Check & Remedy Check connection of the process humidity sensor harness. Case 2 Cause Process humidity sensor trouble Check & Remedy Replace the process humidity sensor. Case 3 Cause PCU PWB trouble Check & Remedy Replace the PCU PWB.
Code: F2 70
Description:
Developing unit improper cartridge detection (Black)
Causes:
When detecting the normal CRUM of the cartridge, improper data are detected in the CRUM contents.
Remedy:
Replace the developing unit
Code: F2 71
Description:
Developing unit improper cartridge detection (Cyan)
Causes:
When detecting the normal CRUM of the cartridge, improper data are detected in the CRUM contents.
Remedy:
Replace the developing unit.
Code: F2 72
Description:
Developing unit improper cartridge detection (Magenta)
Causes:
When detecting the normal CRUM of the cartridge, improper data are detected in the CRUM contents.
Remedy:
Replace the developing unit
Code: F2 73
Description:
Developing unit improper cartridge detection (Yellow)
Causes:
When detecting the normal CRUM of the cartridge, improper data are detected in the CRUM contents.
Remedy:
Case 1 Cause Insertion of an improper cartridge. Developing unit trouble Check & Remedy Replace the developing unit.
Code: F2 74
Description:
Developing unit CRUM trouble (Black)
Causes:
CRUM read/write error
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Code: F2 75
Description:
Developing unit CRUM trouble (Cyan)
Causes:
CRUM read/write error
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.

熱門圖文

相關(guān)資料補充_1維修手冊_錯誤代碼_蘇州sharp維修點售后電話0512-69616769 更新日期2024/8/12 6:57:29

»SHARP復(fù)印機AR-4528U提示需要維護。代碼:TA

»sharpar4818s打A3檢查紙盒:改變紙盒

»Sharp MXC380常見故障代碼描述,英文手冊1

»SHARPAR4818S復(fù)印機有個三角形閃紅燈怎么解決

»SHARP2048N清除H5代碼

»Sharp MX3501N常見故障代碼描述,英文手冊1

»Sharp MX4150FN常見故障代碼描述,英文手冊3

»SHARPAR-1808S打印機重置怎重置??

»Sharp MXM754N常見故障代碼描述,英文手冊02

»SHARPMX-M2608N掃描沒有發(fā)現(xiàn)所選服務(wù)器

»Sharp MX3570N常見故障代碼描述,英文手冊2

»SHARPAR1808S數(shù)字顯示屏上方點三角燈閃爍,是什么問題

»Sharp MXM564N常見故障代碼描述,英文手冊01

»sharpAR4818s一體機復(fù)印出來的一半顏色深一半顏色淺如何設(shè)置

»Sharp MX3550N常見故障代碼描述,英文手冊3


sharp打印機SharpARC262M蘇州sharp平望打印機售后服務(wù)中心電話0512-696l6769,蘇州sharpSharpARC262M平望維修站,sharpSharpARC262M平望維修站,sharpSharpARC262M維修手冊,sharpSharpARC262M驅(qū)動程序下載,sharpSharpARC262M說明書,sharpSharpARC262M故障代碼在線技術(shù)交流,有問必答,sharpSharpARC262M卡紙,打印淺,亮紅燈,不通電,無法使用等故障自己查詢維修資料即可解決問題


熱門關(guān)注
· sharp arc270常見故障代碼描述,英文手冊4

· sharp arc270常見故障代碼描述,英文手冊3

· sharp arc270常見故障代碼描述,英文手冊2

· sharp arc270常見故障代碼描述,英文手冊1

· sharp arc280常見故障代碼描述,英文手冊4

· sharp arc280常見故障代碼描述,英文手冊3

· sharp arc280常見故障代碼描述,英文手冊2

· sharp arc280常見故障代碼描述,英文手冊1

· sharp arc330常見故障代碼描述,英文手冊4

· sharp arc330常見故障代碼描述,英文手冊3

· sharp arc330常見故障代碼描述,英文手冊2

· sharp arc330常見故障代碼描述,英文手冊1

· sharp arc360p常見故障代碼描述,英文手冊2

· sharp arc360p常見故障代碼描述,英文手冊1

· sharp arf151常見故障代碼描述,英文手冊

· sharp arf152常見故障代碼描述,英文手冊

· sharp arf160常見故障代碼描述,英文手冊

· sharp arf161常見故障代碼描述,英文手冊

· sharp arf200常見故障代碼描述,英文手冊

· sharp arf201常見故障代碼描述,英文手冊

· sharp arm150常見故障代碼描述,英文手冊

· sharp arm155常見故障代碼描述,英文手冊

· sharp arm160常見故障代碼描述,英文手冊

· sharp arm161常見故障代碼描述,英文手冊

· sharp arm162常見故障代碼描述,英文手冊

· sharp arm165常見故障代碼描述,英文手冊

· sharp arm200常見故障代碼描述,英文手冊

· sharp arm201常見故障代碼描述,英文手冊

· sharp arm205常見故障代碼描述,英文手冊

· sharp arm206常見故障代碼描述,英文手冊

推薦文章
· shngc-1202-00下載

· sharp1808s掃描儀顯示u-2

· sharp2048n呼叫維修

· sharp2348n恢復(fù)出廠

· sharp打印機出現(xiàn)錯誤代碼h5-1是設(shè)么意思

· sharp打印復(fù)印一體機上面顯示有個人的形狀然后紅燈了是什么意思

· 東芝(toshiba)a4多功能一體機e-studio300d加粉流程圖

· sharp2618nc發(fā)生錯誤。代碼:l4-43

· sharpar2048打印機顯示需要用戶干預(yù)打印不成怎么辦

· toshiba2303卡紙怎去除

· 東芝toshiba2303a打印機提示簡易設(shè)置調(diào)整錯誤請按確定鍵重試

· sharp-mx2018uc 報l14-04代碼,那位大師指點一下

· toshiba2303a復(fù)印機出現(xiàn)e140代碼是什么意思

· sharp ar2008d打印清楚。復(fù)印很淡,手動清楚,調(diào)整方法

· sharp1808s掃描出現(xiàn)u-2

· toshibastudio2303a換碳粉

· sharp mxm700u常見故障代碼描述,英文手冊2

· sharp mxm654fn常見故障代碼描述,英文手冊1

· sharp mxm654fn常見故障代碼描述,英文手冊2

· sharp mxm654fn常見故障代碼描述,英文手冊3

· sharp mxm623u常見故障代碼描述,英文手冊1

· sharp mxm623u常見故障代碼描述,英文手冊2

· sharp mxm620u常見故障代碼描述,英文手冊01

· sharp mxm620u常見故障代碼描述,英文手冊02

· sharp mxm564n常見故障代碼描述,英文手冊01

· sharp mxm564n常見故障代碼描述,英文手冊02

· sharp mxm550u常見故障代碼描述,英文手冊01

· sharp mxm550u常見故障代碼描述,英文手冊02

· sharp mxm503n常見故障代碼描述,英文手冊1

· sharp mxm503n常見故障代碼描述,英文手冊2

· sharp mxm502n常見故障代碼描述,英文手冊2

· sharp mxm502n常見故障代碼描述,英文手冊1

· sharp mxm465n常見故障代碼描述,英文手冊2

· sharp mxm465n常見故障代碼描述,英文手冊1

· sharp mxm464n常見故障代碼描述,英文手冊1

· sharp mxm464n常見故障代碼描述,英文手冊2

· sharp mxm453n常見故障代碼描述,英文手冊1

· sharp mxm453n常見故障代碼描述,英文手冊2

· sharp mxm452n常見故障代碼描述,英文手冊2

· sharp mxm452n常見故障代碼描述,英文手冊1

· sharp mxm450n常見故障代碼描述,英文手冊1

· sharp mxm450n常見故障代碼描述,英文手冊2

· sharp mxm423f常見故障代碼描述,英文手冊1

· sharp mxm423f常見故障代碼描述,英文手冊2

· sharp mxm365n常見故障代碼描述,英文手冊2

· sharp mxm365n常見故障代碼描述,英文手冊1

· sharp mxm364n常見故障代碼描述,英文手冊1

· sharp mxm364n常見故障代碼描述,英文手冊2

· sharp mxm363n常見故障代碼描述,英文手冊2

· sharp mxm363n常見故障代碼描述,英文手冊1