理光sp201sf報(bào)錯(cuò)sc542如何清除,Code: SC542 定影溫度異常
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up o r during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed o r out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position an d it harness connection Check the Fusing lamp an d it harness connection Replace Fusing unit
若以上問(wèn)題無(wú)法解決,歡迎撥打蘇州維修電話696l6769,,上門(mén)維修,,維修
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up o r during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed o r out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position an d it harness connection Check the Fusing lamp an d it harness connection Replace Fusing unit
若以上問(wèn)題無(wú)法解決,歡迎撥打蘇州維修電話696l6769,,上門(mén)維修,,維修