震旦復印機顯示故障代碼c-3723
更新時間:2025/1/28 13:47:35,view:79震旦打印機c-3723蘇州震旦打印機售后服務中心客服熱線69616769,蘇州震旦售后電話,震旦售后網(wǎng)點, 震旦打印機故障代碼c-3723, 震旦369出現(xiàn)C-3723,維修視頻
蘇州震旦維修電話696l6769,維修現(xiàn)場維修
Code C3723 定影高溫故障
Description Fusing abnormally high temperature detection (pressurizing side)
The temperature of the pressure roller continues to be higher than a predetermined level for a predetermined period of time after a temperature correction.
Remedy
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary.
4 Change fusing unit.
5 Change PRCB.
6 Change DCPU
震旦復印機顯示故障代碼c-3723
Code C3723 定影高溫故障
Description Fusing abnormally high temperature detection (pressurizing side)
The temperature of the pressure roller continues to be higher than a predetermined level for a predetermined period of time after a temperature correction.
Remedy
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary.
4 Change fusing unit.
5 Change PRCB.
6 Change DCPU
震旦復印機顯示故障代碼c-3723
熱門圖文