兄弟1608提示無(wú)法打印關(guān)閉電源再次打開(kāi)
更新時(shí)間:2025/1/22 20:42:21,view:412兄弟打印機(jī)1608蘇州兄弟打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州兄弟售后電話,兄弟售后網(wǎng)點(diǎn), 兄弟DCP-1608開(kāi)機(jī)顯示無(wú)法打印怎么辦, 兄弟1608打印機(jī)無(wú)法打印復(fù)印, 兄弟打印機(jī)1608硒鼓碳粉棒不轉(zhuǎn), brotherDCP-1608打印機(jī)加粉后不能打印, 兄弟牌打印機(jī)1608售后,維修視頻
兄弟1608提示無(wú)法打印關(guān)閉電源再次打開(kāi)
兄弟1608售后技術(shù)論壇 DCP1608 2018/9/23 12:06:42 自我診斷十五分鐘后重啟無(wú)法打印05
兄弟1608售后技術(shù)論壇 蔣泡椽 2018/9/23 19:52:59 定影器故障,或相關(guān)驅(qū)動(dòng)電路的問(wèn)題
兄弟1608售后技術(shù)論壇 魏媵蘩 2018/9/23 20:07:20 Code05
Display
Print Unable 05 Turn the power off and then back on again.
Description
The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
Remedy
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness.
3 Connection failure of the eject sensor PCB flat cable Reconnect the eject sensor PCB flat cable.
4 Connection failure of the LVPS harness Reconnect the LVPS harness.
5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
6 Fuser unit failure Replace the fuser unit.
7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
8 Main PCB failure Replace the main PCB ASSY.
![](http://m.ceo99999.com.cn/images/touxiang/41.jpg)
![](http://m.ceo99999.com.cn/images/touxiang/133.jpg)
![](http://m.ceo99999.com.cn/images/touxiang/51.jpg)
Display
Print Unable 05 Turn the power off and then back on again.
Description
The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
Remedy
1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness.
3 Connection failure of the eject sensor PCB flat cable Reconnect the eject sensor PCB flat cable.
4 Connection failure of the LVPS harness Reconnect the LVPS harness.
5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
6 Fuser unit failure Replace the fuser unit.
7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
8 Main PCB failure Replace the main PCB ASSY.